• AWWA WQTC69414
Provide PDF Format

Learn More

AWWA WQTC69414

  • Molecular Testing of Water Samples: New Sample Preparation and Analytical Techniques for Improving Water Monitoring Efficacy
  • Conference Proceeding by American Water Works Association, 11/01/2008
  • Publisher: AWWA

$12.00$24.00


This powerpoint presentation begins by providing a brief overview of molecular testing of drinkingwater, and barriers to PCR use by drinkingwater utilities. AwwaRF Project 3108, "Improving Sample Preparation Methods forMolecular Techniques for Drinking WaterApplications", is presented, having the following goals: to evaluate diverse nucleic acid extraction andpurification techniques to develop an effectivesample preparation method;demonstrate applicability to wide range of watersamples and multiple types of organisms;determine ease, speed, and cost of method; and,perform multiple lab comparisons. The project's scope of work was to:perform a literature review and utility survey;obtain raw and finished water from six participatingutilities;evaluate sample prep techniques and reagents usingnuclease-free water and utility water; and,develop sample prep protocol and test via inter-laboratoryvalidation study. Techniques evaluated included:Lysis buffer- chaotropic salts (e.g., guanidinium isothiocyanate), reducing agents (e.g., 2-mercaptoethanol, DTT, DTE),surfactants (anionic, nonionic, cationic, zwitterionic), andLytic enzymes (e.g., proteinase K, lysozyme);physical disruption- bead beating, sonication; nucleic acid separation- silica column, microconcentrators, magnetic silica beads;PCR inhibition reduction- PVP, PVPP, Sephadex, Sepharose, Chelex-100; and,PCR facilitators. Presentation conclusions indicate the following:a universal sample prep method developedfor molecular detection of viruses, vegetativebacteria, bacterial spores, and parasite(oo)cysts using PCR or RT-PCR;Lysis buffer developed for use with beadbeating, followed by silica column and PVPPcolumn processing;validation study demonstrated that method isreadily and effectively implemented by utilities;no silver bullet for inhibitor removal; and,cost per 500-µL sample: ~$6.50. Includes tables, figures.

Related Products

AWWA MTC64571

AWWA MTC64571

The Englewood, Florida, Brackish Water RO Desalting Plant - 25 Years of Innovation..

$12.00 $24.00

AWWA ACE99552

AWWA ACE99552

Enhancing an Industrial Water Supply Through Creative Water Supply Planning..

$12.00 $24.00

AWWA JAW30353

AWWA JAW30353

Journal AWWA - Contamination of Potable Water by Permeation of Plastic Pipe..

$15.00 $30.00

AWWA ACE71064

AWWA ACE71064

Formation and Stability of Solid Phase Lead Corrosion Products..

$12.00 $24.00