• AWWA MTC64563
Provide PDF Format

Learn More

AWWA MTC64563

  • Reviewing Operational Challenges and Recommendations for the Future
  • Conference Proceeding by American Water Works Association, 03/01/2007
  • Publisher: AWWA

$12.00$24.00


Zone 7 of Alameda County Flood Control and Water Conservation District ownsand operates the Patterson Pass WTP. The conventional plant's process consistsof upflow clarification followed by dual media filtration, with a maximum designcapacity of 13.5 mgd. In an effort to increase the plant's capacity, it was expandedby adding a solids contact clarifier and an Aquasource membrane filtration system.The 8 mgd addition, ultrafiltration WTP, began operating in 2003. Although the UF planthas consistently produced an effluent of acceptable quality, the system hasexperienced difficulties related to operation and meeting its capacity. Anevaluation was conducted to identify options to optimize the UF WTP operationand to more reliably meet its 8 mgd capacity, and to identify alternatives forincreasing the capacity to 10-12 mgd. The evaluation consisted of reviewingoperating data and conducting a site visit to gather information about the plantoperating procedures and past performance. Issues were identified that createoperating difficulties and ultimately restrict the ability of the system to reliablymeet its 8 mgd design capacity. One of the key issues identified is failure of thewater quality from the pretreatment unit to meet the membrane feed water qualityrequirements, primarily the iron concentrations which exceed the membranewarranty limits. In addition, issues such as diurnal pH fluctuations, algae growth,and return of neutralized citric acid cause process upsets that increase the iron andparticle loading on the membranes. Analysis of the membranes has shownirrecoverable fouling (loss of permeability) and accelerated aging of themembranes, which have been linked to elevated iron concentrations. Includes tables, figure.

Related Products

AWWA DSS71298

AWWA DSS71298

Distribution System Flushing: Meeting Stakeholder Expectations..

$12.00 $24.00

AWWA WQTC56947

AWWA WQTC56947

The Impact of Turbidity on Cryptosporidium and Giardia Inactivtion by Ultraviolet Light..

$12.00 $24.00

AWWA JAW31538

AWWA JAW31538

Journal AWWA - From Conventional to Biological Removal of Iron and Manganese in France..

$15.00 $30.00

AWWA WQTC71442

AWWA WQTC71442

Microbial Contamination and Climate Change: Examples from Recent Floods..

$12.00 $24.00