• AWWA ACE70917
Provide PDF Format

Learn More

AWWA ACE70917

  • Greater Cincinnati Water Works: The Great Tennyson Pump Station Mystery
  • Conference Proceeding by American Water Works Association, 11/01/2009
  • Publisher: AWWA

$12.00$24.00


This powerpoint presentation begins by providing a brief overview of the Greater Cincinnati Water Works (GCWW), with special focus on the Tennyson Pump Station and the issue of inconsistency with pumping 100 MGD. Hydraulic transient analysis was performed, and an attempt was made to bring all 6 pumps online under the following two scenarios: Scenario 1 - start EH pumps under normal conditions andbring CS pumps online by manually isolating all the primeto the pump and bleed air from casing, keeping cone checkclosed until adequate pressure is developed and then openvalve; and, Scenario 2 - have EH pumps running and bring CS pumpson during "normal" operation (i.e., normal priming conditionand no air relief from casing) except cone check valve heldclosed until adequate pressure reached. Includes tables, figures.

Related Products

AWWA ACE61844

AWWA ACE61844

Economics of Domestic Residential Water Meter Replacement Based on Cumulative Volume..

$12.00 $24.00

AWWA ACE65428

AWWA ACE65428

Water Distribution Main Lining and Service Connection Reinstatement..

$12.00 $24.00

AWWA WQTC63972

AWWA WQTC63972

An Evaluation of the Operational Issues Associated with UV Disinfection..

$12.00 $24.00

AWWA MTC64557

AWWA MTC64557

Comparison of Electrocoagulation and Chemical Coagulation for Microfiltration Pretreatment of Natura..

$12.00 $24.00