• AWWA ACE62951
Provide PDF Format

Learn More

AWWA ACE62951

  • Pre-treatment with Magnetic Ion Exchange Resin to Reduce TOC, DBP Precursors, and Residuals Production
  • Conference Proceeding by American Water Works Association, 06/01/2006
  • Publisher: AWWA

$12.00$24.00


This slide presentation outlines research on pretreatment with magnetic ion exchange resin to reduce total organic carbon (TOC), disinfection byproduct (DBP) precursors, and residuals production. Goals of new treatmentstrategies for Canyon Road included: improve TOC and DBP precursor removal;improve turbidity applied to filters; flexibility to respond to challenging conditions; and,reduce or limit operational complexity. Turbidity implications duringMay/June snowmelt runoff are outlined and include: MIEX alone;contact clarifier (coarse media,upflow filter) and dissolved air flotation (DAF);plate settler without MIEX; and,plate settler with MIEX. Turbidity and filter headloss (36 min. floc., plate settler, and filter skid) in September 2005 is outlined and included:without MIEX - turbidity - with and without non-ionic poly, andfilter headloss; and, with MIEX - turbidity - with and without non-ionic poly, andfilter headloss. Organic contaminants were evaluated for: color; DBP precursor removal; and,molecular weight scan. Research on residuals included: impact of lower alum dose with MIEX; and, brine from MIEX. Outline summary includes: alum with versus without MIEX indicatedsettled turbidity lower with MIEX, and without MIEX could not reduce 5-day DBP SDS <64/48,but could with MIEX + alum;goals were achieved with MIEX at 4 to 6 timeslower alum dose than without MIEX;lower alum dose means less challenge to clarifiersand filters, and less residuals handling; and,MIEX adds new residuals stream (brine waste).Other observations included:36 minutes flocculation needed without MIEX (24 with MIEX);alum + LT22s worked with and without MIEXwhen no MIEX, non-ionic also needed, but with MIEX, non-ionic produced unacceptably high filterheadloss (at doses tested). Includes figures.

Related Products

AWWA 51572

AWWA 51572

Experiences With Planning, Construction and Start-up of a 14.5 MGD Microfiltration Facility..

$12.00 $24.00

AWWA SOURCES55573

AWWA SOURCES55573

Tailored Rates..

$12.00 $24.00

AWWA ACE56191

AWWA ACE56191

Integration of Membranes into Existing Water Treatment Works..

$12.00 $24.00

AWWA ACE62954

AWWA ACE62954

Treating Waste Filter Backwash and Sedimentation/Coagulation Sludges to Meet NPDES Permit Limits At ..

$12.00 $24.00