  • Strategies for Indirect Low Pressure Membrane Integrity Monitoring
  • Conference Proceeding by American Water Works Association, 06/17/2005
  • Publisher: AWWA

$12.00$24.00


Effective contaminant removal using MF/UF processes assumes that there is no feed water bypassingthe membrane through defects in the membrane module. One of the important issues in the practicalapplication and proper regulatory acceptance of these processes involves the methods of monitoringmembrane integrity. This manuscript evaluates data collected in pilot and full-scale evaluations ofintegrity monitoring tools in the context of the requirements of the Long Term 2 Enhanced SurfaceWater Treatment Rule (LT2) specific to continuous indirect integrity monitoring.The current draft of LT2 stipulates minimum membrane integrity monitoring methods. A maximumdirect integrity monitoring interval of 24 hours and continuous turbidity monitoring are required. Thedocument also calls for an action limit for direct testing, based on a maximum filtrate water turbidity of0.15 NTU. In certain cases, this limit might be only indicative of a major membrane system failure. Inthe case of a major integrity failure occurring between integrity tests, it is feasible that the maximumfiltered water turbidity would not be exceeded, but required log removal may not be met. Two pilot-scale evaluations were performed. The first involveda single, full-scale membrane module mounted on a pilot-scale plant was operated under a protocolapproved by the California Department of Health Services. The membrane, provided by Westech Engineering (Salt Lake City, Utah), was an outside to inside flow, polysulfone membrane operating indeposition mode. The module contains 1227 square feet of active membrane surface area, is rated at anominal pore size of 0.01 microns by the manufacturer (Polymem). Challenge testing was performed atUnited Water Idaho's Marden Water Treatment Plant. The testing took place in three phases that included: MS-2 bacteriophage challenge testing; surrogate evaluation of Cryptosporidium removal; and, integrity evaluation. The second pilot-scale evaluation involved a single, full-scale membrane module mounted a pilot-scale plant was operated under a protocolapproved by the California Department of Health Services. The membrane, provided by inge Americas(Northbrook, IL), was an inside to outside flow, polyethersulfone membrane operating in depositionmode. The module contained 485 square feet of active membrane surface area, was rated at a nominalmolecular weight cutoff of 100-150 kD by the manufacturer (inge, AG). Challenge testing wasperformed at the City of Redlands' Horace Hinckley Water Treatment Plant. The testing involved four phases that included: MS-2 challenge testing; microsphere challenge testing; compromised membrane challenge testing; and, operational characteristics. The testing of various integrity monitoring techniques in this work was performed on a single full-scalemembrane rack at selected water treatment plants. Four ofthe participating plants are located in the U.S., while the remaining two are located internationally. Theconcentrated full-scale testing at each participating plant was performed for a period of two months.The plants participating in this project were selected to represent the existing range of commerciallyavailable membrane systems and manufacturers. Direct methods tested included the pressure decay testand online sonic testing. Indirect monitoring methods tested included particle counting at varioussensitivities, index based particle monitoring, count based particle monitoring, turbidity monitoring,laser turbidity monitoring, multi-sensor laser turbidity monitoring. Includes 4 references, tables, figures.

Related Products

AWWA ACE54307

AWWA ACE54307

Water Conservation for Diverse Land-Use Communities..

$12.00 $24.00

AWWA WQTC60693

AWWA WQTC60693

Practical Modeling of Chlorine and Chloramine Decay in Drinking Water..

$12.00 $24.00

AWWA PATH50796

AWWA PATH50796

Factors Affecting the Culture of Helicobacter pylori: An Emerging Waterborne Pathogen..

$12.00 $24.00

AWWA ACE91110

AWWA ACE91110

Adding the Personal Touch to Community Relations..

$12.00 $24.00