• AWWA ACE59901
Provide PDF Format

Learn More

AWWA ACE59901

  • NDMA Formation from Water Treatment Polymers
  • Conference Proceeding by American Water Works Association, 06/17/2004
  • Publisher: AWWA

$12.00$24.00


This project focused on investigating the impact of various parameters on the formation ofNDMA upon chloramination of organic polymers used in drinking water treatment. Specifically,the project was designed to answer the following questions:do anionic or nonionic polymers used in drinking water treatment also form NDMA;what is the impact of polymer dose on NDMA formation;what is the impact of chloramine contact time on NDMA formation;what is the impact of free chlorine contact time, upstream of ammonia addition, ondownstream NDMA formation;what is the impact of water pH on NDMA formation from polymers; and,do the polymer storage conditions affect its potential to form NDMA? While the testing was conducted in organic-free deionized laboratory water, itsresults should provide specific insights to water agencies on how to manage the chloramine-polymerinteraction and minimize NDMA formation at their plants.All bench-scale activities were conducted by Water Quality & Treatment Solutions (WQTS) at the Environmental EngineeringLaboratory of the University of California, Los Angeles (UCLA). NDMA samples were analyzedby the Water Quality Laboratory of the Metropolitan Water District of Southern California(MWDSC). All DMA samples were analyzed by Dr. David Sedlak's research group at theUniversity of California Berkeley (UCB). At the beginning of the project, WQTS conducted asurvey of the polymers used by the sponsoring agencies. Based on the results of the survey,WQTS and the agency representatives advising WQTS on the project selected twelvepolymers to be evaluated. Eight of these polymers were cationic polymers, two wereanionic polymers, and two were nonionic polymers.The bench-scale tests focused on contacting polymer solutions with chloramine under variouswater quality and experimental conditions, and analyzing the product water for NDMA and DMA.Seven tests were initially planned andconducted, but two additional tests were added later on in the project. In all tests, varioussolutions of polymers were prepared in Nanopure® water. With the exception of Test 3, thechemical addition sequence was chlorine, followed by ammonia, and then followed by polymer.The chloraminated water was first prepared in bicarbonate-buffered Nanopure® water. Thealkalinity of the buffered water was maintained between 95 and 100 mg/L as CaCO<sub>3</sub>. Thechloraminated water was then split into amber glass bottles to which the target polymer doseswere added. All chemical solutions were prepared in Nanopure® water. Includes 11 references, tables, figures.

Related Products

AWWA ACE91067

AWWA ACE91067

Modeling Effects of Bromide Ion Concentration on the Formation of Brominated Trihalomethanes..

$12.00 $24.00

AWWA SOURCES66607

AWWA SOURCES66607

Using an End Use Model to Quantify Demand Hardening from Long-Term Conservation Programs..

$12.00 $24.00

AWWA REUSE52107

AWWA REUSE52107

Water Reuse in Eastern Saudi Arabia..

$12.00 $24.00

AWWA JTMGT57498

AWWA JTMGT57498

Facilitating Political Acceptance of a Rate Change..

$12.00 $24.00