• AWWA ACE54250
Provide PDF Format

Learn More

AWWA ACE54250

  • Meeting the Challenges of the New Arsenic Rule: Conventional Treatment of Surface/Groundwater Blends
  • Conference Proceeding by American Water Works Association, 06/01/2001
  • Publisher: AWWA

$12.00$24.00


The proposed Arsenic Rule currently under review by the Environmental Protection Agency has the potential to present significant challenges to a large number of drinking water purveyors in complying with a lower arsenic standard. SierraPacific Power Company (Sierra) in Reno, Nevada is one of the purveyors that will be affected by the new rule. Sierra's water production occurs from 2 surface water treatment plants and 29 wells. A significant fraction of these production wells have arsenic and Sierra (and its customers) will be affected, though the extent depends upon the standard set in the final rule. For example, if the standard is set at 5 ppb, then 23 of Sierra's 29 wells would violate the maximum contaminant level (MCL). An economical option, in Sierra's estimation, is to utilize the existing conventional treatment plant facilities for the removal ofarsenic from groundwater exceeding the MCL. This paper details the findings from research that was conducted to determine the effectiveness of coagulation for the removal of arsenic from various blends of ground and surface water. Full scaletesting was conducted to determine the arsenic removal effectiveness of the existing treatment process (conventional treatment with alum) at the Glendale Water Treatment Plant. Additional bench-scale evaluation (jar testing) was conducted to determine the influence on arsenic removal of process variables such as pH, coagulant (alum and ferric chloride) and coagulant dose. Optimal arsenic removal via conventional treatment (with alum) occurred in the pH range 5-7.5. Raw water (blended) arsenic concentrations in the range of 25-60 ppb were successfully treated to a final (post-filtration) arsenic concentration lessthan 10 ppb in this pH range (alum dose approximately 20 mg/L). Ferric chloride was also shown to be effective in the same pH range (in bench-scale tests) for blends of well/surface water ranging from 25% to 100% well water. Includes table, figures.

Related Products

AWWA JAW26124

AWWA JAW26124

Journal AWWA - Developing a Data Base on Infrastructure Needs ..

$15.00 $30.00

AWWA WQTC55178

AWWA WQTC55178

Largest Unfiltered Ozonation Plant: Water Quality Impacts..

$12.00 $24.00

AWWA WQTC52959

AWWA WQTC52959

Coliform Bacteria and Escherichia coli in Norwegian Drinking Water Sources - Comparison of Methods B..

$12.00 $24.00

AWWA ACE61868

AWWA ACE61868

An Innovative Technique for Controlling Nitrification in Chloraminating Systems..

$12.00 $24.00