1.1 This practice covers procedures for the design, preparation, and use of axially loaded, tension test specimens and fatigue pre-cracked (fracture mechanics) specimens for use in slow strain rate (SSR) tests to investigate the resistance of metallic materials to environmentally assisted cracking (EAC). While some investigators utilize SSR test techniques in combination with cyclic or fatigue loading, no attempt has been made to incorporate such techniques into this practice.

1.2 Slow strain rate testing is applicable to the evaluation of a wide variety of metallic materials in test environments which simulate aqueous, nonaqueous, and gaseous service environments over a wide range of temperatures and pressures that may cause EAC of susceptible materials.

1.3 The primary use of this practice is to furnish accepted procedures for the accelerated testing of the resistance of metallic materials to EAC under various environmental conditions. In many cases, the initiation of EAC is accelerated through the application of a dynamic strain in the gage section or at a notch tip or crack tip, or both, of a specimen. Due to the accelerated nature of this test, the results are not intended to necessarily represent service performance, but rather to provide a basis for screening, for detection of an environmental interaction with a material, and for comparative evaluation of the effects of metallurgical and environmental variables on sensitivity to known environmental cracking problems.

1.4 Further information on SSR test methods is available in ISO 7539 and in the references provided with this practice (1-6).

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Furthermore, in some cases, special facilities will be required to isolate these tests from laboratory personnel if high pressures or toxic chemical environments, or both, are utilized in SSR testing.

Related Products

ASTM F311-08(2013)

ASTM F311-08(2013)

Standard Practice for Processing Aerospace Liquid Samples for Particulate Contamination Analysis U..

$20.00 $39.00

ASTM D2383-97

ASTM D2383-97

Standard Practice for Testing Plasticizer Compatibility in Poly(Vinyl Chloride) (PVC) Compounds Unde..

$23.00 $46.80

ASTM D5010-01e1

ASTM D5010-01e1

Standard Guide for Testing Printing Inks and Related Materials..

$26.00 $52.80

ASTM D4646-03(2008)

ASTM D4646-03(2008)

Standard Test Method for 24-h Batch-Type Measurement of Contaminant Sorption by Soils and Sediments..

$20.00 $39.00